Diesel Generator Sets

Deutz diesel generator set

Our company produces deutz generator set selection of Germany imported deutz, weichai deutz, hechai deutz diesel engine to complete sets. As a producer of Deutz diesel generator sets, the Deutz generator sets produced by ShengdongNew Energy are featured by advanced technology, small size, low fuel consumption and low noise, which are trusted by the majority of users.


Online consultationNational hotline
0393-8903-977

11.jpg 

Ⅰ、Introduction of Deutz Diesel Generator Set

Our company produces deutz generator set selection of Germany imported deutz, weichai deutz, hechai deutz diesel engine to complete sets. As a producer of Deutz diesel generator sets, the Deutz generator sets produced by ShengdongNew Energy are featured by advanced technology, small size, low fuel consumption and low noise, which are trusted by the majority of users.

Deutz, founded in 1864 and headquartered in Cologne, Germany, is the world's oldest and leading independent engine manufacturer. Deutz is the world's first internal combustion engine manufacturer. As a specialist in a full range of engines, deutz provides water and air cooled engines for a wide range of engineering machinery, generator sets, agricultural machinery, commercial vehicles, railway locomotives and ships, as well as for a wide range of professional supporting applications. Deutz supports its customers with 9 distribution companies, 9 sales offices, 16 service centers and more than 800 sales and service partners in more than 130 countries.

Deutz diesel engine, which is based on German technology, the structure is compact, large power, high efficiency, strong adaptability to environment and high reliability combine together, every moment let users understand the many compelling advantages, it now has more than 400000 units, according to Mr. Diesel generator reliably running all over the world, they have gained themselves the trust of the broad masses of users, Deutz diesel generator features low fuel consumption, small size, light weight, high reliability and durability, low vibration, low noise, easy operation and maintenance. It is a successful example of Sino-German cooperation.


Main specifications, models and technical parameters of Deutz diesel generator set

7777.png

Unit electrical indicators: rated frequency 50Hz (60Hz optional); Power factor COSФ=0.8; Rated voltage 400/230V; Phase line: three-phase four-wire system;

If you need to know more information about the unit, Deutz diesel generator set quotation or not shown the power model of the unit parameters please contact us.


Ⅲ、Technical description of generator set

1. Standard environmental conditions for the operation of generator sets

Atmospheric pressure 100kPa; Ambient temperature 25℃; Relative humidity 30%; Under the above conditions, when the fuel quality meets the technical requirements, the generator set can reach the rated load output.

2. Product design to follow standard specificatio

Including but not limited to the following mentioned standards and specifications: ISO9001, GB/T 2820-2009, JB/T 10303-2001, GB/T 15548-2008, GB/T 20136-2006, etc.

3. When the generator set is on standby

When the generator set is on standby for a long time, it can be started manually on a regular basis and run without load to self-check its startup performance.

4. The fuel used

No. 0 light diesel oil should be selected in summer, and no. -10, no. -20 or no. -35 light diesel oil should be selected in winter according to regional climate conditions.

5. Lubricating oil system

The lubrication system of the generator set is a closed self-circulation lubrication system. Engine with organic oil tank (oil sump), oil pump, manual/electric pre-supply oil pump, oil filter, oil cooler, etc.

6. Cooling system

Cooling water should be slightly alkaline clean water, without corrosive compounds. Its main indicators are as follows: hardness 0.7 ~ 5.3mol/L, chloride ion content < 150mg/L, pH value 6 ~ 8.5. Antifreeze should be used in winter.

7. Start the system

The generator set adopts DC motor to start, and the working power supply is DC 24V. The battery is equipped with an automatic charging device, which can be automatically charged to ensure that the battery has sufficient power.

 Generator Set Configuration Scheme

(一)The standard configuration

1. Direct injection internal combustion engine (diesel);

2. AC synchronous generator (single bearing);

3. Suitable for the environment of 40℃-50℃ radiator water tank, belt driven cooling fan, fan safety cover;

4. Power generation output air switch, standard control panel;

5. Unit steel common base (including: unit vibration damping rubber pad);

6. Dry air filter, fuel filter, lubricating oil filter, starting motor, and equipped with self-charging generator;

7. Start the battery and the battery start connection cable;

8. Standard parts for industrial 9dB mufflers and connectors;

9. Random data: original technical documents of diesel engine and generator, generator set manual, test report, etc.

(二)Optional configuration

1. Oil, diesel oil, water jacket, anti-condensation heater;

2. Split type daily fuel tank, integrated base fuel tank;

3. Battery floating charger;

4. Rainproof unit (box);

5. Self-protection, self-starting unit control panel;

6. Silent unit (cabinet);

7. With "three yao" function unit control panel;

8. Mobile towing vehicle power station (box trailer);

9. ATS automatic load conversion screen;

10. Silent mobile power station (box trailer);

trailer);

After-sales service

Warranty period: 12 months after the commissioning and acceptance of domestic units or a total of 

Warranty period: 12 months after the commissioning and acceptance of domestic units or a total of 1000 hours of operation; Subject to the first due date. Due to product quality problems to implement free maintenance or replacement, lifetime paid service! (wearing parts, commonly used parts, man-made damage, neglect maintenance are not within the scope of the warranty) such as due to the original factory adjustment to the original warranty regulations!

After the shelf life, users enjoy life-long maintenance of the product, the replacement of accessories only charge cost, no additional fees for labor. In case of serious wear and tear or special circumstances, you can go to our company for overhaul or replacement. If you find the product inconvenient to use or need our technical support, you can call our after-sale service team. Our company will be the first time after receiving a phone call or fax to send a specialist rushed to the site for inspection and maintenance, in order to restore the normal operation of the product at the fastest speed.


Deutz Generator Installation Notes

1. The installation site shall be well ventilated. The generator end shall have enough air inlet and the diesel engine end shall have good air outlet. The air outlet area should be more than 1.5 times the area of the water tank;

2. The surrounding of the installation site should be kept clean, avoid placing items that can produce acid, alkaline and other corrosive gases and vapors nearby. Conditional should be equipped with fire extinguishing devices.

3. If used indoors, the smoke exhaust pipe must be connected to the outdoor, the pipe diameter must be greater than the silencer smoke pipe diameter, the pipe elbow should not be more than 3, to ensure the smooth smoke exhaust, and the pipe should be inclined downward 5--10 degrees, to avoid rain injection; If the exhaust pipe is installed vertically, a rain shield must be installed.

4. When the foundation is concrete, the levelness shall be measured with a level ruler during installation to make the unit fixed on the horizontal foundation. There should be special shockproof pad or bottom bolt between the unit and the foundation.

5. The unit shell must have reliable protective grounding. For generators requiring direct grounding of the neutral point, the neutral grounding must be carried out by professionals and equipped with lightning protection device.

6. The two-way switch between the generator and the mains must be very reliable to prevent backfeeding. The wiring reliability of the two-way switch shall be inspected and approved by the local power supply department.

7. The wiring of starting battery must be firm.